5.11. Diagnostics of malfunctions of system of indication of level of liquid
REASON
|
WAY OF ELIMINATION
| |
The control bulb flashes at the working engine and normal the level of cooling liquid | The sensor is faulty | Check an ohmmeter, if necessary, replace. |
Short circuit on the case in the electric line | Check the line according to the schematic diagram of electric equipment. | |
The indicator device is faulty | Replace. | |
The control bulb at inclusion of system of ignition does not flash | The bulb is faulty | Sort and check. |
Break of a wire | Check electric lines according to the schematic diagram of electric equipment. | |
The indicator device is faulty | Replace. | |
The control bulb at the working engine and an empty compensation tank does not vspykhivyat | The sensor is faulty | Check an ohmmeter, if necessary, replace. |
Break of a wire | Check electric lines according to the schematic diagram of electric equipment. |