5.11. Diagnostics of malfunctions of system of indication of level of liquid

REASON
WAY OF ELIMINATION
The control bulb flashes at the working engine and normal the level of cooling liquid The sensor is faulty Check an ohmmeter, if necessary, replace.
Short circuit on the case in the electric line Check the line according to the schematic diagram of electric equipment.
The indicator device is faulty Replace.
The control bulb at inclusion of system of ignition does not flash The bulb is faulty Sort and check.
Break of a wire Check electric lines according to the schematic diagram of electric equipment.
The indicator device is faulty Replace.
The control bulb at the working engine and an empty compensation tank does not vspykhivyat The sensor is faulty Check an ohmmeter, if necessary, replace.
Break of a wire Check electric lines according to the schematic diagram of electric equipment.