8.2.5. The sensor of the soaked-up air
The thermal sensor takes temperature of the soaked-up air. This size together with a signal of the sensor of pressure of the inlet gas pipeline (system of PMS management) serves as criterion for evaluation of amount of the let-in air. Tremodatchik of the soaked-up air is the NTC resistor (NTC – negative temperature coefficient) which resistance decreases at temperature increase.
The thermal sensor is located on the left side of a cross pipe of the air filter.
Removal
PERFORMANCE ORDER | ||
|
Check
PERFORMANCE ORDER | ||||
|
Installation
PERFORMANCE ORDER | |||
|
Thermal sensor resistance
TEMPERATURE
|
RESISTANCE
|
+10 °C
|
apprx. 9670 Ohms
|
+20 °C
|
apprx. 6060 Ohms
|
+30 °C
|
apprx. 3900 Ohms
|
+40 °C
|
apprx. 2600 Ohms
|
+50 °C
|
apprx. 1760 Ohms
|
+60 °C
|
apprx. 1220 Ohms
|
+70 °C
|
apprx. 860 Ohms
|
+80 °C
|
apprx. 620 Ohms
|